Packaging Testing Equipment And Solutions

Members are provided with comprehensive ways to promote their products, maximizing product exposure and increasing return-on-investment. With the help of dedicated and hard working team of professionals, we are identified as a highly reputedimporter, distributor, exporter, and stockistin the Indian market. These personnel source products from reliable and trustworthy world reputed mfrs. In a short span of time, we have established ourselves in the local as well as global market. We have extensive experience with bioabsorbable polymers, polyurethanes, ultra-high molecular weight polyethylene, polyetheretherketone, nylons and other polymers that are used for implants or medical products. Contact us to learn more about our capabilities and experience with testing and analyzing plastics. SGS PSI has decades of experience solving complex challenges involving plastics.

Our film specialists analyze data gathered during testing to make recommendations for a better performing film or to help troubleshoot an existing problem. Blog Take a deeper dive into packaging equipment, materials, and news about Atlantic with our Blog. Industrial Paperboard Converting Versatility in the breadth of paper products we can create and the range of industries we can serve. Flexible Packaging The Atlantic team has 40 years experience with bagging equipment, barrier films and logistics. Shrink Packaging Expertise on films, equipment, and application to create a near zero down-time environment. Strapping Strapping systems ideal for your products, volume, and design of your full packaging line.

cap torque tester

PTI is the leading manufacturer of non-destructive package inspection technologies for the pharmaceutical, medical device and food industries. PTI’s airborne ultrasound technology is highly effective for seal quality testing and analysis. VeriPac and Seal-Scan technologies offer non-destructive inspection solutions for flexible package quality testing. Polymer and plastics chemical testing supporting the entire lifecycle including chemicals analysis of polymer raw materials, resins, plastics and composites. C203H Oxygen TransmissionRate Test System is based on Coulometric oxygen analysis sensor andequal pressure test metod, and is conforming to ASTM D 3985 and otherstandards. It provides high-precision and high-efficiency oxygen permeabilitytests for high and medium gas barrier materials. We provide our industry partners with service and support for their quality control requirements, production assessments, and procurement decisions. It is of utmost importance to ensure that correct packaging materials are used for drug product. This test is used only with containers that have been exposed to sulphur dioxide fumes under controlled humidity conditions. The principle involved in the water attack test is to determine whether the alkali leached form the surface of a container is within the specified limits or not.

For an SVP with a daily dose volume of 10 mL, the resulting AET of 0.15 µg/mL can be challenging to achieve in chemically complicated parenterals. For an LVP with a daily dose volume of 1 liter, the AET of 1.5 ppb can be challenging in even the simplest parenteral drug product. Such an “AET challenge” makes extractables and leachables profiling even more difficult. Simply stated, the health of patients using drug products is adversely affected in direct proportion to the dose of leachables to which they are exposed, with the greatest adverse effect occurring at the highest dose of the most toxic substances. Parenterals are classified by volume; a small volume parenteral has a solution volume per unit package of 100 mL or less and is intended for intermittent intravenous administration (usually defined as an infusion time not lasting longer than 6-8 hours). SVPs can be packaged in ampules, vials, prefilled syringes, bottles, and plastic bags. If the friction of a material is too high then the film may too ‘tacky’ for the process, too low and the film may be too ‘slippy’ for the process. Optimising friction parameters can help understand how the finish of a blown film can influence the feeding and running speed. Surface slip is a key factor when printing or filling packaging materials on an automated line.

CMTL strives to provide a high level of technical support and quality service to each of our customers because when you succeed we succeed. Cambridge Materials Testing Limited is an independent laboratory servicing a broad range of clients. The company’s operations include two facilities in southern Ontario located in Cambridge and Mississauga, Ontario. We believe that independant third party testing is a cost effective way to protect and limit liability for all parties involved in supplying any manufactured product or production process. The packaging operation can involve many complex operations, all of which require careful control if product quality and security are to be maintained. The packaging operation means either the filling and packaging of non sterile products or the packaging stage of filled sterile products. The main specifications requirements are the component drawing, artwork and the quality control testing and standards. a) Water vapour permeability- the water vapour permeability of the pack containing the product is required. This is necessary because although the bottles will comply with the water vapour permeability test described in USP, permeation through the bottle wall will depend on wheather the product has a high or low affinity for the water. The test split into two parts to enable the maximum amount of information to be obtained and hence possibly eliminating the necessity to perform further time consuming experiments.

Since a couple of years, there has been an increasing demand for use of plastic sacks and plastic packings. Because of its non-biodegradation process, plastic represents a genuine danger to nature. Packaging industry comprehended the future outcome of using the plastic packaging and moved to paper sacks and paper packings as a substitute. Be that as it may, clients set aside some great benefits which they were getting from plastic packets. It is great honor to be a technical innovation enterprise and gain the government support. Top-load testers provide a reliable and accurate solution for meeting design standards and are often sited close to filling lines in production or nearby in the QC laboratory. They may also be applied for testing aluminium and steel cans, large cardboard boxes and plastic or metal drums.

Often the package is conditioned to the specified environment and tested under those conditions. With some testing, the package is conditioned to a specified environment, then is removed to ambient conditions and quickly tested. With some types of packaging such as food and pharmaceuticals, chemical tests are conducted to determine suitability of food contact materials. Testing programs range from simple tests with little replication to more thorough experimental designs. PET containers have numerous points of interest over different structures, similar to, glass. These are a portion of the regular advantages of utilizing a PET, yet the greatest preferred standpoint is that it is anything but difficult to re-evaluate the plan of plastic pressing in the event that it is bombing over and again. The revaluation procedure does not cost the fortune to the organization but rather unquestionably requires a correct testing process.

Sustainability Program Helping you find the sustainable packaging products that work best for your products. Making better decisions using the obtained information in regard to the design of the package and the distribution process. This is an important step in which the operator must ensure that the sample is not tilted to either side in order to obtain accurate results. Once this test has been performed and the exact dimensions of the samples to be tested have been determined, the ASTM D638 method outlines 5 sample types. The ASTM D638 method is applied to rigid plastic samples with sizes ranging from 1.00 mm to 14 mm thick. Simply complete the form below and the BPF will send your enquiry on to relevant companies who can supply the material you are looking for. Thermal testing consists of either measuring the HDT or VICAT softening point. PerkinElmer uses cookies to ensure that we give you the best experience possible on our website. If you continue without changing your settings, we will assume that you consent to receive cookies from this website. To learn more, please review our cookie policy, which includes information on how to manage your cookies.

Peel strength is the average load per unit width of bond line required to separate bonded materials where the angle of separation is 180⁰. Bursting strength of combined board is an optional requirement of the various carrier regulations for shipping containers. The bursting strength of the component paperboard is an important control test in the paperboard mill since the conformity of the finished container is generally controlled by the bursting strength of the paperboard. This is a compression machine specifically adapted to test the stacking load / top load carrying capacity of Blow Molded bottles & jars. This machine can also be adopted to test other blow molded products like Trays, Cups, etc. Saicheng™ can help you inspect the physical property of packaging materials and improve the shelf life by controlling packaging quality. Airborne ultrasound technology is one of the most effective non-destructive testing methods for flexible packages.